Website Name

Home > New Arrivals > New Arrivals

Xinhua Surgical Instrument recently launched percutaneous transforaminal endoscopic discectomy, one milestone to spinal minimally invasive field

2017-08-05 15:36:10 Website Name Read

1493695671592289.png


Lumbar disc herniation is due to lumbar disc degeneration, fibrous ring rupture, the clinical symptoms of nucleus pulposus prolapse or after nerve root compression or cauda equina is shown, is the leading cause of clinical common disease and pain, bring a lot of pain to the patient's life and work, and even the loss of labor ability. Transforaminal discectomy is the most safe and effective method for the treatment of lumbar disc herniation.

Foraminal mirror from the patient side or the rear side into the intervertebral foramen, operation in the security triangle, bone tissue throughout the process of endoscopic direct observation on nucleus pulposus, dural sac and nerve root, hyperplasia, the use of all kinds of catch forcepsunder nucleus pulposus tissue, or in endoscopic removal of bone, RF repair damaged fiber ring electrode. Transforaminal endoscopic surgery procedures can be summarized as positioning, channel establishment, removal of nucleus pulposus in three steps, which, according to the established channel in different ways, divided into two ways and trephine bone drill grinding on the facet tip channel establishment.



1493695768132219.png


   In view of the development of the technique of intervertebral foramen endoscope surgery, Xinhua surgical instruments Co., Ltd. has launched a special set of surgical instruments for intervertebral foramen endoscope:

 

1493695830130902.png

1493695878116977.png

Nucleus forceps

0SL]$PPG_]@XS~2QBGCLE5T.png

Curved grasping forceps

1493696255461946.png

Bite and cut forceps (Lan Qian)


1493696624460440.png

Rongeur

1493696676130037.png

Bone drill

1493696723341543.png

Endoscopic trephine

1493696777114460.png

Trephine

1493696823465302.png

Positioner (TOM pin)

1493697258133691.png

The handle, the handle trephine bone drill

1493697311586351.png

Trepan putter

1493697357103809.png

Regulator and Kirschner wire

_@U7]9Z2E6NTZPDB7I)W34N.png

Guide wire

1493697436472876.png

Three stage expansion tube

1493697563303072.png

Trephine expansion tube

1493697622745783.png

Work sleeve

1493703501756068.png

Nerve dissector

1493703569622239.png

Nerve retractor

1493703611744449.png

Bone knife

ECVW4B7EYAG]`14S_731L@B.png

Puncture needle

1493703697108194.png

Bone hammer

This set of instruments has the following characteristics:

1) the head of the nucleus pulposus, the cutting forceps and so on, adopt a fine addition molding technology to ensure the consistency of products and good shearing properties, and improve the corrosion resistance of the products;

2) bone drill forming technology to avoid the risk of fracture at the end of the head;

3) the bone drill uses a unique cutting edge design to remove the chip from the body;

4) advanced deep hole processing technology, bone drill hole roughness can reach the specular level, ensure smooth guide bone penetration, avoid deformation of jam;

5) products covered by trephine and bone drill two channel establishing method, to meet the different choice of surgical methods;

6) high performance price ratio is the best choice to replace imported intervertebral hole mirror instruments.